Wall Mounted Fog System
#FOG-IT6 SystemWall mounted, air and electricity powered, fog system. The control box is configurable to your needs with up to 20 nozzles and a dispense timer.
Wall mounted, air and electricity powered, fog system. The control box is configurable to your needs with up to 20 nozzles and a dispense timer.
compressed air, electricity
draws from pre-mixed solution
one product
8 ft. (2.4 m) hose with 3/8 in. (9.5 mm) inside diameter
WITH FG-NA-N130 NOZZLES: 7.9 oz/min (0.23 l/min)
WITH FG-NA-26SS NOZZLES: 5.3 oz/min (0.16 l/min)
Santoprene, Viton, or Kalrez
WITH FG-NA-N130 NOZZLES: Polypropylene and Kynar
WITH FG-NA-26SS NOZZLES: Celcon, stainless steel, EPDM and nylon
delay on make single shot
WITH FG-NA-N130 NOZZLES: 15 microns at 50 psi (3.4 bar)
WITH FG-NA-26SS NOZZLES: 35 microns at 50 psi (3.4 bar)
1 liter of solution will cover approximately 1000 cubic feet**
WITH FG-NA-N130 NOZZLES: flat pattern with projection up to 10 ft. (3 m) from nozzle
WITH FG-NA-26SS NOZZLES: pattern up to 8 ft. (2.4 m) wide (side to side) and 3 ft. (0.9 m) thick (top to bottom), with projection up to 15 ft. (4.6 m) from nozzle
WITH FG-NA-N130 NOZZLES: 1-20 nozzles per control box
WITH FG-NA-26SS NOZZLES: 1-12 nozzles per control box
designed for use with 3/8 in. (9.5 mm) outside diameter tubing between control box and nozzle(s)
*dilution rates and flow rates given are based on chemical with viscosity of water and factory air pressure settings.
**area covered and run time may vary based on humidity, air flow, and product used.
***number of nozzles is dependent upon air supply (see Compressed Air Requirements)
WITH FG-NA-N130 NOZZLES: at factory air pressure setting of 50 psi (3.4 bar): 2 cfm (56.6 l/min) for control box, plus 2.5 cfm (70.8 l/min) per nozzle
maximum incoming air pressure: 150 psi (10.3 bar)
WITH FG-NA-26SS NOZZLES: at factory air pressure setting of 50 psi (3.4 bar): 2 cfm (56.6 l/min) for control box, plus 5 cfm (142 l/min) per nozzle
maximum incoming air pressure: 150 psi (10.3 bar)
40-100˚F (4.4-37˚C)
120 VAC at 60 Hz, 2 amps (GFCI protected outlet)
120 VAC
Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or SDS for your product or contact our customer service department.
Control Box:
PUMP SEAL MATERIAL | |
---|---|
MU-6 | Santoprene (standard) |
Viton (V) | |
Kalrez (K) |
Add option codes to item number as shown. For standard options, no option code is needed. Examples:
nozzle assemblies (sold separately):
ordering example:
for a system with one control box with Santoprene pump seals and eight FG-NA-26SS nozzles, the order would be as follows:
QUANTITY | ITEM NUMBER |
---|---|
1 | MU-6 |
8 | MU-NA-26SS |
Choose a pump seal material that is compatible with the chemicals you will use. Chemical incompatibility can cause accelerated wear and equipment failure that is not covered by warranty, so it’s important to do your research.